Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Ordenar por: 

RelevânciaAutorTítuloAnoImprime registros no formato resumido
Registros recuperados: 3
Primeira ... 1 ... Última
Imagem não selecionada

Imprime registro no formato completo
Angiotensin-(1-7) relieved renal injury induced by chronic intermittent hypoxia in rats by reducing inflammation, oxidative stress and fibrosis BJMBR
Lu,W.; Kang,J.; Hu,K.; Tang,S.; Zhou,X.; Yu,S.; Xu,L..
We aimed to study the renal injury and hypertension induced by chronic intermittent hypoxia (CIH) and the protective effects mediated by angiotensin 1-7 [Ang(1-7)]. We randomly assigned 32 male Sprague-Dawley rats (body weight 180-200 g) to normoxia control, CIH, Ang(1-7)-treated normoxia, and Ang(1-7)-treated CIH groups. Systolic blood pressure (SBP) was monitored at the start and end of each week. Renal sympathetic nerve activity (RSNA) was recorded. CTGF and TGF-β were detected by immunohistochemistry and western blotting. Tissue parameters of oxidative stress were also determined. In addition, renal levels of interleukin-6, tumor necrosis factor-α, nitrotyrosine, and hypoxia-inducible factor-1α were determined by immunohistochemistry, immunoblotting,...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Ang(1-7); Renal injury; Obstructive sleep apnea; Inflammation; Oxidative stress; Fibrosis.
Ano: 2017 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017000100604
Imagem não selecionada

Imprime registro no formato completo
Comparative efficacy and safety of contact force-sensing catheter and second-generation cryoballoon ablation for atrial fibrillation: a meta-analysis BJMBR
Zhou,X.; Lv,W.; Zhang,W.; Ye,Y.; Li,Y.; Zhou,Q.; Zhang,J.; Xing,Q.; Lu,Y.; Zhang,L.; Wang,H.; Qin,W.; Tang,B..
This meta-analysis compared the efficacy and safety of the contact force (CF)-sensing catheter and second-generation cryoballoon (CB) ablation for treating atrial fibrillation (AF). Six controlled clinical trials comparing ablation for AF using a CF-sensing catheter or second-generation CB were identified from PubMed, EMBASE, Cochrane Library, Wanfang Data, and China National Knowledge Infrastructure. The procedure duration was significantly lower in the CB group compared with that in the CF group [mean difference (MD)=29.4; 95%CI=17.84–40.96; P=0.01], whereas there was no difference between the groups for fluoroscopy duration (MD=0.59; 95%CI=–4.48–5.66; P=0.82). Moreover, there was no difference in the incidence of non-lethal complications (embolic event,...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Atrial fibrillation; Ablation; Contact force-sensing catheter; Second-generation cryoballoon; Meta-analysis.
Ano: 2017 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017000900607
Imagem não selecionada

Imprime registro no formato completo
Angiotensin-(1–7) inhibits inflammation and oxidative stress to relieve lung injury induced by chronic intermittent hypoxia in rats BJMBR
Lu,W.; Kang,J.; Hu,K.; Tang,S.; Zhou,X.; Yu,S.; Li,Y.; Xu,L..
Obstructive sleep apnea is associated with inflammation and oxidative stress in lung tissues and can lead to metabolic abnormalities. We investigated the effects of angiotensin1–7 [Ang-(1–7)] on lung injury in rats induced by chronic intermittent hypoxia (CIH). We randomly assigned 32 male Sprague-Dawley rats (180–200 g) to normoxia control (NC), CIH-untreated (uCIH), Ang-(1–7)-treated normoxia control (N-A), and Ang-(1–7)-treated CIH (CIH-A) groups. Oxidative stress biomarkers were measured in lung tissues, and expression of NADPH oxidase 4 (Nox4) and Nox subunits (p22phox, and p47phox) was determined by Western blot and reverse transcription-polymerase chain reaction. Pulmonary pathological changes were more evident in the uCIH group than in the other...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Ang-(1–7); Lung injury; Obstructive sleep apnea; Inflammation; Oxidative stress; Chronic intermittent hypoxia.
Ano: 2016 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2016001000603
Registros recuperados: 3
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional