Cunha,Gisele C. de A.; Lopes Neto,José P.; Furtado,Dermeval A.; Borges,Valéria P.; Freire,Elias A.; Nascimento,José W. B. do. |
ABSTRACT Negative pressure ventilation in poultry houses has been used to enable the correction of their internal microclimates, and studies point to the heterogeneous distribution of air along the aviaries and the inadequacy of the environmental variables to the recommended ranges for thermal comfort of adult birds, especially in the hottest hours of the day. This study aimed to diagnose the facilities of a poultry house in the state of Paraíba, Brazil, regarding the distribution of environmental variables and thermal comfort; develop a computational model and validate it for Computational Fluid Dynamic - CFD simulations. Air temperature (Tair), air relative humidity (RH) and air velocity (Vair) data allowed characterizing the internal environment by... |
Tipo: Info:eu-repo/semantics/article |
Palavras-chave: Thermal comfort; Thermal index; Simulations. |
Ano: 2019 |
URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1415-43662019001000761 |
| |