Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Registro completo
Provedor de dados:  ArchiMer
País:  France
Título:  Spectrophotometric Winkler determination of dissolved oxygen: re-examination of critical factors and reliability
Autores:  Labasque, Thierry
Chaumery, Christian
Aminot, Alain
Kergoat, Gilles
Data:  2004-08
Ano:  2004
Palavras-chave:  Isobestic point
Sea water
Spectrophotometry
Dissolved oxygen
Resumo:  The spectrophotometric iodine measurement for oxygen determination by the Winkler method is re-examined for theoretical and operational aspects. It is shown that the selection of an isobestic point for measuring the mixture of iodine and tri-iodide in the solution enhances reliability. The wavelength value of 466 nm was selected after a spectrum study. Then, performances are assessed by mean of statistical approach based on repeated standardization curves at the isobestic point compared with other wavelengths. At 466 nm, the method is linear up to about 1000 mumol kg(-1) of O-2. Optimization and validation of the spectrophotometric method is realized through a robustness study based on factors that may alter the results (temperature, reagent volumes, storage time). Temperature is the only factor that exerts a significant influence on the absorbance (0.5% per degreesC), hence samples and standards should be kept at the same temperature within +/-1 degreesC. Precision was estimated over a 10-day period. The standard deviation was 0.45% for inter-sample repeatability and 0.73% for reproducibility near 250 mumol kg(-1). The repeatability of 12 samples taken at the same immersion was around 0.12%. The detection limit, determined from standardization curves, is <2 mumol kg(-1). Accuracy was verified with O-2 saturated seawater and found to be within the precision confidence interval. The method can be applied to the determination of dissolved oxygen in fresh or seawater samples, suboxic, or waters supersaturated in dissolved oxygen. It is suggested as being a suitable alternative to titration in most applications of the Winkler determination of dissolved oxygen. (C) 2004 Elsevier B.V. All rights reserved.
Tipo:  Text
Idioma:  Inglês
Identificador:  http://archimer.ifremer.fr/doc/2004/publication-1694.pdf

DOI:10.1016/j.marchem.2004.03.004
Editor:  Elsevier
Relação:  http://archimer.ifremer.fr/doc/00000/1694/
Formato:  application/pdf
Fonte:  Marine Chemistry (0304-4203) (Elsevier), 2004-08 , Vol. 88 , N. 1-2 , P. 53-60
Direitos:  2004 Elsevier B.V. All rights reserved
Fechar
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional