Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Registro completo
Provedor de dados:  Ciência e Agrotecnologia
País:  Brazil
Título:  Elemental concentration via portable x-ray fluorescence spectrometry: Assessing the impact of water content
Autores:  Santana,Monna Lysa Teixeira
Carvalho,Geila Santos
Guilherme,Luiz Roberto Guimarães
Curi,Nilton
Ribeiro,Bruno Teixeira
Data:  2019-01-01
Ano:  2019
Palavras-chave:  Proximal sensors
X-ray scattering
Spectroscopy analysis.
Resumo:  ABSTRACT Portable X-ray fluorescence (pXRF) analysis can be considered one of the main recent advances for chemical characterization of earth materials. The water content of the samples can affect the pXRF performance. As a novelty, we aimed to establish relationships (linear regression) between the effect of water content on pXRF results and atomic number (Z) of the elements. Three certified reference materials (CRM) were investigated: OREAS 100a, OREAS 101a, and OREAS 101b. These materials were saturated (0.68 g g-1) with distilled water and left to air-dry naturally. During the drying, the elemental concentrations (C) were determined at different water contents using a pXRF spectrometer. For each water content, the ratio Cwet/Cdry was determined and plotted against the water content. The attenuation coefficient (σ) was also determined. High σ values mean more influence of water content upon measurement element concentration. The obtained recovery rates allowed a qualitative determination. The concentration for the most elements reduced linearly with increasing water content. A predictable behavior of the water content on pXRF results as function of atomic number was not found. Elements identified by Lα spectral line with highest Z were more impacted by water content than elements identified by Kα line with lowest Z. Ti, Cr and Fe was not significantly influenced by water content, and Sr was the most impacted. Our findings contribute to decision-making before characterization earth materials via pXRF, obliging the use of dry samples for determination of impacted elements or by using moisture-corrected data.
Tipo:  Info:eu-repo/semantics/article
Idioma:  Inglês
Identificador:  http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-70542019000100205
Editor:  Editora da Universidade Federal de Lavras
Relação:  10.1590/1413-7054201943029218
Formato:  text/html
Fonte:  Ciência e Agrotecnologia v.43 2019
Direitos:  info:eu-repo/semantics/openAccess
Fechar
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional