Título:  Intraocular pressure measurements with the Tono-Pen XL® and Perkins® applanation tonometers in horses and cattle
Autores:  Andrade,Silvia Franco
Palozzi,Rodrigo de Jesus
Rolim,Rodrigo Duarte
Junqueira,José Ricardo Cecílio
Valle,Heloisa Ferreira do
Silva,Marcelo Kurak da
Maia,Marcelo Augusto
Zampiere,Rodrigo Augusto
Data:  2013-05-01
Ano:  2013
Palavras-chave:  Applanation tonometer
Cattle
Horses
Perkins tonometer
Tono-Pen XL tonometer
Resumo:  The objective of this study was to compare the accuracy between two applanation tonometers, Tono-Pen XL® and Perkins®, in horses and cattle. The eyes of 20 horses and 20 cattle conscious and healthy were evaluated for the in vivo study and both eyes of 5 horses and 5 cattle were used as controls for the postmortem study. In conscious animals, the tonometry was performed with auriculopalpebral nerve block and then topical anesthesia for both tonometers and 1% fluorescein eye drops only for the Perkins tonometer. Readings of intraocular pressure (IOP) in the postmortem study were taken using manometry and tonometry by Tono-Pen XL® and Perkins®. The correlation coefficient (r²) between manometry and applanation tonometers Tono-Pen XL® and Perkins®, in horses, were 0.845 and 0.989, respectively, and in cattle, were 0.772 and 0.988, respectively. The mean IOP values in conscious horses with Tono-Pen XL® and Perkins® were 20.1±3.9mmHg and 20.9±3.2mmHg, respectively, and in conscious cattle, these values were 17.2±2.4mmHg and 17.9±1.4mmHg, respectively. There was a strong correlation between the IOP values obtained by direct ocular manometry and the Tono-Pen XL® and Perkins® tonometers in horses and cattle. There was no statistically significant difference between the mean IOPs obtained with both tonometers in conscious animals; however, there was a difference between the minimum values, which were on average 2-3 mmHg lower with the Tono-Pen XL® tonometer than with the Perkins® tonometer, which justifies a table of normal values differentiated for each tonometer.
Tipo:  Info:eu-repo/semantics/article
Idioma:  Inglês
Identificador:  http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782013000500018
Editor:  Universidade Federal de Santa Maria
Relação:  10.1590/S0103-84782013005000030
Formato:  text/html
Fonte:  Ciência Rural v.43 n.5 2013
Direitos:  info:eu-repo/semantics/openAccess
Fechar
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional