Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Ordenar por: 

RelevânciaAutorTítuloAnoImprime registros no formato resumido
Registros recuperados: 2
Primeira ... 1 ... Última
Imagem não selecionada

Imprime registro no formato completo
Structure and Concentration of Elastic System Fibers in the Trachea of the Rat International Journal of Morphology
Andrade,Filipe Moreira de; Judice,Luiz Felippe; Cisne,Rafael; Félix,Bruno; Mourad,Omar Moté Abou; Cardoso,Gilberto Perez; Babinski,Marcio Antonio.
The extracellular matrix is a key element in the tracheal morphology and physiology, both in normal and pathological states, yet little is known regarding its composition and organization. Herein we carried out a detailed study of the morphological organization and volumetric density of elastic system fibers in the trachea of Wistar rats. Six Wistar rats at the age of 45 days were used. The trachea was excised following anesthesia with Thiopental and perfusion through the left ventricle with buffered saline followed by formalin solution. Samples were fixed in formaline, embedded in paraffin, and histologically processed. The elastic system fibers were evaluated at light microscopy by using Weigert's resorcin-fuchsin technique after oxidation with oxone....
Tipo: Journal article Palavras-chave: Rat; Trachea; Morphology; Elastic fibers; Quantitative evaluation.
Ano: 2011 URL: http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022011000100002
Imagem não selecionada

Imprime registro no formato completo
Morphometric Study of the Proximal Femur Extremity in Brazilians International Journal of Morphology
de Sousa,Eduardo Branco; Fernandes,Rodrigo Mota Pacheco; Mathias,Marcelo Bezerra; Rodrigues,Mauro Roberto; Ambram,Albert James; Babinski,Marcio Antonio.
Brazilian populational aging besides higher life expectancy has increased the incidence of proximal femoral fractures. Treatment of those fractures uses implants which are based in measurements performed in caucasians, including the 135 degrees cervical-diaphyseal angle. Knowing femoral morphometry allows evaluating implants adequability. We performed our study using 110 Brazilian human femurs (49 right and 61 left). We excluded from the study: bones submitted to osteosyntesis, to prosthetization or those showing abnormalities or malformations which could affect its structure and shape. Bones were submitted to roetgenographic analysis and the images were scanned and transferred to personal computer. Measurements were obtained by AutoCad software and...
Tipo: Journal article Palavras-chave: Femur; Morphometry; Anatomy.
Ano: 2010 URL: http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022010000300027
Registros recuperados: 2
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional