Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Ordenar por: 

RelevânciaAutorTítuloAnoImprime registros no formato resumido
Registros recuperados: 2
Primeira ... 1 ... Última
Imagem não selecionada

Imprime registro no formato completo
Validation of an analytical method by high-performance liquid chromatography and microbiological assay, biological safety and in silico toxicity for danofloxacin BJPS
Cordeiro,Everson Willian Fialho; Hilgert,Renata Medeiros; Batista,Luiz Alcides das Chagas; Souza,Raul Oliveira; Oliveira,Luís Flávio Souza de; Machado,Michel Mansur; Malesuik,Marcelo Donadel; Paula,Fávero Reisdorfer; Stopiglia,Cheila Denise Ottonelli; Paim,Clésio Soldateli.
Danofloxacin is a veterinary fluoroquinolone used to treat respiratory and gastrointestinal diseases of birds, pigs and cattle. The literature reviewed shows some analytical methods to quantify this fluoroquinolone, but microbiological and biological safety studies are limited. The analytical methods were validated by the Official Codes. The LC-DAD method was developed and validated using an RP-18 column, mobile phase containing a mixture of 0.3% triethylamine (pH 3.0) and acetonitrile (85:15, v/v). The microbiological assay was performed by agar diffusion method (3 x 3) and Staphylococcus epidermidis as a microorganism test. Forced degradation studies were performed in both methods. The minimum inhibitory concentration (MIC) was performed by test...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Danofloxacin; Microbiological assay; Biological safety; In silico toxicology; Fluoroquinolones photodegradation.
Ano: 2020 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502020000100555
Imagem não selecionada

Imprime registro no formato completo
Development and characterization of an immunoaffinity column for the detection of danofloxacin residues in milk samples Ciênc. Tecnol. Aliment.
NIU,Rui; YANG,Yamei; WANG,Yadan; LUO,Shilong; ZHANG,Cheng; WANG,Yun.
Abstract In this study, an immunoaffinity column was prepared by covalently coupling of polyclonal antibody against danofloxacin (DAN) with chitosan microparticles and its potential application to selective extraction of DAN from food samples was also evaluated. The produced antibody exhibited high sensitivity, with an IC50 value of 4.56 ng/mL towards DAN, and good specificity, with less than 0.5% of cross-reactivity towards DAN structurally related compounds. The developed immunoaffinity column had an approximate binding capacity of 2300 ng/mL gel and a relative standard deviation (RSD) of 3.7% among columns. The immunoaffinity columns were then challenged with DAN-fortified milk samples, recoveries of DAN were found to be in the range of 83.8% to 98.8%,...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Danofloxacin; Immunoaffinity chromatography; Clean-up; Residual detection.
Ano: 2019 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612019000200500
Registros recuperados: 2
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional