Determination of Rare Earth Elements, Sc, Y, Zr, Ba, Hf and Th in Geological Samples by ICP-MS after Tm Addition and Alkaline Fusion ArchiMer
Bayon, Germain; Barrat, Jean Alix; Etoubleau, Joel; Benoit, Mathieu; Bollinger, Claire; Revillon, Sidonie.
We present a revised method for the determination of concentrations of rare earth (REE) and other trace elements (Y, Sc, Zr, Ba, Hf, Th) in geological samples. Our analytical procedure involves sample digestion using alkaline fusion (NaOH-Na2O2) after addition of a Tm spike, co-precipitation on iron hydroxides, and measurement by sector field-inductively coupled plasma-mass spectrometry (SF-ICP-MS). The procedure was tested successfully for various rock types (i.e., basalt, ultramafic rock, sediment, soil, granite), including rocks with low trace element abundances (sub ng g(-1)). Results obtained for a series of nine geological reference materials (BIR-1, BCR-2, UB-N, JP-1, AC-E, MA-N, MAG-1, GSMS-2, GSS-4) are in reasonable agreement with published...
Tipo: Text Palavras-chave: Digestion des Echantillons; Spike de Tm; ICP MS; MatEriaux de rEfErence; Echantillons gEologiques; ElEments du groupe des Terres Rares; Sample digestion; Tm spike; ICP MS; Reference materials; Geological samples; Rare earth elements.
Ano: 2009 URL: http://archimer.ifremer.fr/doc/2009/publication-6449.pdf
Imagem não selecionada

Imprime registro no formato completo
Quantitative analysis by energy dispersive X-ray fluorescence by the transmission method applied to geological samples Scientia Agricola
Simabuco,S.M.; Nascimento Filho,V.F..
Three certified samples of different matrices (Soil-5, SL-1/IAEA and SARM-4/SABS) were quantitatively analysed by energy dispersive X-ray fluorescence with radioisotopic excitation. The observed errors were about 10-20% for the majority of the elements and less than 10% for Fe and Zn in the Soil-5, Mn in SL-1, and Ti, Fe and Zn in SARM-4 samples. Annular radioactive sources of Fe-55 and Cd-109 were utilized for the excitation of elements while a Si(Li) semiconductor detector coupled to a multichannel emulation card inserted in a microcomputer was used for the detection of the characteristic X-rays. The fundamental parameters method was used for the determination of elemental sensitivities and the irradiator or transmission method for the correction of the...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Quantitative analysis; X-ray fluorescence; Geological samples; Energy dispersive.
Ano: 1994 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-90161994000200001
Registros recuperados: 2
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional