Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Ordenar por: 

RelevânciaAutorTítuloAnoImprime registros no formato resumido
Registros recuperados: 2
Primeira ... 1 ... Última
Imagem não selecionada

Imprime registro no formato completo
Stability-indicating RP-HPLC method for determination of beclomethasone dipropionate in nanocapsule suspensions BJPS
Chassot,Janaíne Micheli; Ferreira,Luana Mota; Gomes,Felipe Pereira; Cruz,Letícia; Tasso,Leandro.
abstract A simple stability-indicating RP-HPLC/UV method was validated for determination of beclomethasone dipropionate (BD) in nanocapsule suspensions. Chromatographic conditions consisted of a RP C18column (250 mm x 4.60 mm, 5 µm, 110 Å), using methanol and water (85:15 v/v) as mobile phase at 1.0 mL/min with UV detection at 254 nm. The calibration curve was found to be linear in the concentration range of 5.0-25.0 µg/mL with a correlation coefficient > 0.999. Precision was demonstrated by a relative standard deviation lower than 2.0%. Accuracy was assessed by the recovery test of BD from nanocapsules (98.03% to 100.35%). Specificity showed no interference from the components of nanocapsules or from the degradation products derived from acid, basic...
Tipo: Info:eu-repo/semantics/article Palavras-chave: High performance liquid chromatography/reverse phase/quantitative analysis; Beclomethasone dipropionate/determination; Nanocapsule/suspensions; Nanoparticles..
Ano: 2015 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502015000400803
Imagem não selecionada

Imprime registro no formato completo
Determination of amphotericin B in PLA-PEG blend nanoparticles by HPLC-PDA BJPS
Rodrigues,Caroline Danziato; Khalil,Najeh Maissar; Mainardes,Rubiana Mara.
In this work, we developed and validated an effective reversed-phase HPLC method with photodiode array (PDA) detection for the quantitative analysis of amphotericin B (AmB) in poly(lactide)-poly(ethylene glycol) (PLA-PEG) blend nanoparticles. Chromatographic runs were performed on a reverse phase C18 column using a mobile phase comprising a 9% acetic acid and acetonitrile mixture (40:60, v/v) under isocratic elution with a flow rate of 1 mL/min. AmB was detected at a wavelength of 408 nm. The validation process was performed considering the selectivity, linearity, precision, accuracy, robustness, limit of detection (LOD) and limit of quantitation (LOQ) of the method. A concentration range of 1-20 µg/mL was used to construct a linear calibration curve. The...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Amphotericin B/determination; Amphotericin B/encapsulation; High performance liquid chromatography/reverse phase/quantitative analysis; Nanoparticles.
Ano: 2014 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502014000400859
Registros recuperados: 2
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional