Abstract: the pneumatic precision metering device for wheat was innovated, designed and tested under laboratory conditions. Very good results were then obtained according to the precision seeding criteria based on quality of feed index (QFI), miss index (MIS) and multiple index (MULI). To optimize the structure of the design for gas stability before manufacturing, ANSYS-CFX was involved. Gas behavior was simulated under different shapes and positions for pressure inlet along with different seed hole diameters. According to the structure determined in ANSYS-CFX, the seed hole of 1.8 mm and cylindrical shape of pressure inlet was found to be the best among others, accordingly the deice was then manufactured and tested under laboratory and field conditions.... |