Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Ordenar por: 

RelevânciaAutorTítuloAnoImprime registros no formato resumido
Registros recuperados: 6
Primeira ... 1 ... Última
Imagem não selecionada

Imprime registro no formato completo
Radioguided surgery for breast cancer: preliminary experience in Piaui BABT
Abreu,Benedita; Melo,Nayana; Vieira,Sabas; Abreu,Evandro; Abreu,João Batista de; Pádua Filho,Antonio de.
Intraoperatory detection and excision of sentinel lymph node (SLN), radioguided occult lesion localization (ROLL) and lesional resection, or a combination of these two procedures at one time in a same patient (SNOLL), are techniques that represent, at the moment, a significant advance in breast cancer surgery, procedures in clinical practice being established, as can be seen from the medical literature, as well as in this institution. Thirty-one patients with breast cancer were initially treated with the aid of radioguided surgery. Of those, 20 patients were submitted to sentinel lymph node biopsy, six have undergone only ROLL and five were submitted to a combination of the two techniques.
Tipo: Info:eu-repo/semantics/article Palavras-chave: Breast cancer; Sentinel lymph node; Intraoperative probe.
Ano: 2005 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132005000700020
Imagem não selecionada

Imprime registro no formato completo
Problems and pitfalls in vulvar and cervical cancer sentinel node scintigraphy BABT
Sinzinger,Helmut; Granegger,Susanne; Palumbo,Barbara; Palumbo,Renato.
After the introduction for penile cancer, the sentinel lymph node imaging is increasingly applied in various types of cancer. After the initial learning phase, 105 patients with vulvar and 24 with cervical cancer have been investigated. In vulvar cancer all the imaged sentinel nodes were discovered by the portable probe intraoperatively. No false negative sentinel node was observed. The most critical issue is the tracer application. Performed strictly intradermally, the sentinel node shows up immediately. Concomitant use of isosulfan blue dye did not improve the results and was stopped therefore. Similarly, more superficial (intra/subendothelial) application brings up better results as compared to deeper injection in cervical cancer patients. No false...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Sentinel lymph node; Vulvar cancer; Cervical cancer; Scintigraphy.
Ano: 2008 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132008000700007
Imagem não selecionada

Imprime registro no formato completo
Sentinel lymph node detection through radioguided surgery in patients with breast cancer BABT
Abreu,Benedita Andrade Leal de; Santos,Adriana de Morais; Soares,Lívia de Almeida; dos Santos,Antônio Ricardo; Barros,Idna de Carvalho; Abreu,Everardo Leal de; Cruz Filho,Alexandre Jorge Gomes da; Abreu,João Batista de; Vieira,Sabas Carlos.
Biopsy of the sentinel lymphnode (SLNB), the first lymphnode to receive lymphatic drainage from the primary tumor, accurately predicts the axillary lymph node status and, when negative, obviates the need for axillary lymphadenectomy (AL). The aim of this study was, to verify the SLN localization in breast cancer through preoperative lymphoscintigraphy and intraoperative gamma-probe, as well as to demonstrate the benefits of such techniques in preventing complications of AL. Medical records of 228 patients with breast carcinoma, who were underwent SLN localization and, radioguided surgery, from March 2005 to December 2007 were analyzed retrospectively. Data regarding age, tumor characteristic, breast involved, type of surgery, radiopharmaceutical drainage...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Breast cancer; Sentinel lymph node; Lymphoscintigraphy; Intraoperative probe.
Ano: 2008 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132008000700010
Imagem não selecionada

Imprime registro no formato completo
Sentinel node biopsy using blue dye and technetium99 in advanced gastric cancer: anatomical drainage and clinical application BJMBR
Santos,F.A.V.; Drummond-Lage,A.P.; Rodrigues,M.A.; Cabral,M.A.; Pedrosa,M.S.; Braga,H.; Wainstein,A.J.A..
Lymph node metastases are an independent prognosis factor in gastric carcinoma (GC) patients. Radical lymphadenectomy can improve survival but it can also increase surgical morbidity. As a principle, sentinel node (SN) navigation surgery can avoid unnecessary lymphadenectomy without compromising prognosis. In this pilot study, 24 patients with untreated GC were initially screened for SN navigation surgery, of which 12 were eligible. Five patients had T2 tumors, 5 had T3 tumors and 2 had T1 tumors. In 33% of cases, tumor diameter was greater than 5.0 cm. Three hundred and eighty-seven lymph nodes were excised with a median of 32.3 per patient. The SN navigation surgery was feasible in all patients, with a median of 4.5 SNs per patient. The detection success...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Gastric carcinoma; Sentinel lymph node; Biopsy; Stage.
Ano: 2016 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2016000800701
Imagem não selecionada

Imprime registro no formato completo
Sentinel node biopsy in breast cancer: results in a large series BJMBR
Carvalho,S.M.T.; Mourão Netto,M.; Lima,E.N.P.; Pimentel,A.M.; Makdissi,F.B.; Osório,C.A.B.T.; Maciel,M.S.; Iyeyasu,H.; Collins,J.B.; Fontes,C.M.; Perina,A.L.; Soares,F.A..
Sentinel lymph node biopsy (SLNB) is an appropriate method for the evaluation of axillary status in cases of early breast cancer. We report our experience in treating cases evaluated using SLNB. We analyzed a total of 1192 cases assessed by means of SLNB from July 1999 to December 2007. SLNB processing was successfully completed in 1154 cases with the use of blue dye or radiolabeled 99mTc-Dextran-500, or both. Of these 1154 patients, 857 were N0(i-) (no regional lymph node metastasis, negative immunohistochemistry, IHC), 96 were N0(i+) (no regional lymph node metastasis histologically, positive IHC, no IHC cluster greater than 0.2 mm) and 201 were N1mi (greater than 0.2 mm, none greater than 2.0 mm). Most of the tumors (70%) were invasive ductal carcinomas...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Breast neoplasms; Sentinel lymph node; Sentinel lymph node biopsy; Completion axillary dissection.
Ano: 2010 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2010000600011
Imagem não selecionada

Imprime registro no formato completo
Prevalence of vascular-endothelial growth factor, matrix metalloproteinases and tissue inhibitors of metalloproteinases in primary breast cancer BJMBR
Jobim,F.C.; Xavier,N.L.; Uchoa,D.M.; Cruz,D.B.; Saciloto,M.; Chemello,N.; Schwartsmann,G..
Our objective was to determine the presence of vascular endothelial growth factor (VEGF), matrix metalloproteinase-2 (MMP-2) and MMP-9 and specific tissue inhibitors of matrix metalloproteinase (TIMP-1 and TIMP-2) in tumor samples obtained from patients with primary breast cancer. We attempted to correlate these findings with the status of the sentinel lymph node (SLN) and clinical-pathological characteristics such as age, tumor size, histological type, histological grade, and vascular invasion. Tumor samples from 88 patients with primary breast cancer were analyzed. The immunoreactivity of VEGF, MMP-2, MMP-9, TIMP-1, and TIMP-2 in tumors was correlated with clinical and pathological features, as well as SLN status. Nonparametric, Mann-Whittney,...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Breast cancer; Vascular endothelial growth factor; Matrix metalloproteinase; Metalloproteinase tissue inhibitors; Sentinel lymph node.
Ano: 2009 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2009001000018
Registros recuperados: 6
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional