Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Registro completo
Provedor de dados:  Arq. Bras. Med. Vet. Zootec.
País:  Brazil
Título:  Retrospective study of ocular complication following phacoemulsification with intraocular acrylic lens implantation in dogs
Autores:  Guimarães,T.G.
Honsho,C.S.
Mamede,F.V.
Dias,F.G.G.
Anjos,D.S.
Pereira,L.F.
Ricordi,I.
Jorge,A.T.
Data:  2017-08-01
Ano:  2017
Palavras-chave:  Cataract
Phakectomy
Hydrophilic lens
Hydrophobic lens
Resumo:  ABSTRACT The aim of this study was to analyze for 120 days, post-operative complications following bimanual phacoemulsification with implantation of hydrophilic or hydrophobic intraocular acrylic lens. The hospital records of 15 dogs were analyzed, and distributed in two groups, being Gfi and Gfo the hydrophilic intraocular lens and hydrophobic intraocular lens group, respectively. On the first day, both groups presented blepharospasm, conjunctival hyperemia and flare. On day 1, fibrin was slightly apparent in two and three eyes of Gfi and Gfo, and on day 7, present in one and two patients from Gfi and Gfo. Synechia was observed on day 1 in one eye from Gfi and Gfo. Two eyes from Gfi developed from 7 to 120 days, and in Gfo, one eye developed from 7 to 90 days, on day 120, two eyes formed them. The presence of posterior capsule opacity of the lens in all periods, there was no statistical significant between the groups. Only one eye, in Gfo, that had no opacity formation. The intraocular pressure of both groups remained within normal range. There was no statistical significance between hydrophilic and hydrophobic intraocular lens, the use of intraocular lens has led to satisfactory results in visual ability.
Tipo:  Info:eu-repo/semantics/article
Idioma:  Inglês
Identificador:  http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352017000400915
Editor:  Universidade Federal de Minas Gerais, Escola de Veterinária
Relação:  10.1590/1678-4162-9229
Formato:  text/html
Fonte:  Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.69 n.4 2017
Direitos:  info:eu-repo/semantics/openAccess
Fechar
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional