Calibration of a capacitance probe in a Paleudult
|
Autores: |
Silva,Cláudio Ricardo da
Andrade Júnior,Aderson Soares de
Alves Júnior,José
Souza,Antonio Barros de
Melo,Francisco de Brito
Coelho Filho,Maurício Antonio
|
Data: |
2007-12-01
|
Ano: |
2007
|
Palavras-chave: |
FDR probe
Sensor
Irrigation
Soil water content
|
Resumo: |
The use of capacitance sensors is one of the methods used to quantitatively measure soil water contents (theta, m³ m-3). Sensors provide readings at desired depths and time intervals. A capacitance probe (Diviner 2000) was calibrated for a Rhodic Paleudult from the Piaui State, Brazil. Six access tubes were installed in a 5 × 2 m grid arrangement. Three moisture levels (saturated, moist and dry) were used in two replications. Probe readings and soil samplings to determine theta were made at 0.1 m depth intervals down to a depth of 1.0 m. A power calibration equation was developed for each depth as well as for the entire soil profile (Root Mean Square Error = 0.014, R² = 0.93) for a theta range of 0.068 to 0.264 m³m-3. A separate calibration for each depth improves the correlation coefficient and minimizes RMSE. Site-specific calibration improves the accuracy for soil water monitoring.
|
Tipo: |
Info:eu-repo/semantics/report
|
Idioma: |
Inglês
|
Identificador: |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-90162007000600012
|
Editor: |
São Paulo - Escola Superior de Agricultura "Luiz de Queiroz"
|
Relação: |
10.1590/S0103-90162007000600012
|
Formato: |
text/html
|
Fonte: |
Scientia Agricola v.64 n.6 2007
|
Direitos: |