Título:  Development and validation of a data logger for thermal characterization in laying hen facilities
Autores:  Freitas,Letícia C. da S. R.
Tinôco,Ilda de F. F.
Gates,Richard S.
Barbari,Matteo
Cândido,Márcia G. L.
Toledo,João V.
Data:  2019-10-01
Ano:  2019
Palavras-chave:  Electronic device
Environmental monitoring
Poultry facilities
Resumo:  ABSTRACT The environmental monitoring in animal facilities that includes collected data storage in a robust, practical and feasible way is a constant challenge. The aim of this study was to develop a reliable data logger for monitoring the air temperature and air relative humidity of aviaries and to assess the adequacy of the design using commercially available reference standard instruments. The experimental data logger was installed together with a commercial data logger, a mercury thermometer and a calibrated Vaisala HMP110 air relative humidity probe in a meteorological shelter. Linear regression analysis was performed with the collected air temperature and air relative humidity to develop calibration equations. The Nash-Sutcliffe Index and the relative error were calculated to validate the experimental data logger. The air temperature and the air relative humidity calibration equations presented Nash-Sutcliffe of 0.993 and -0.281 for the commercial data logger, and 0.913 and 0.932 for the experimental data. The mean relative error of the air temperature readings was 3 and 1% and for air relative humidity 5 and 20%, for the experimental and commercial logger, respectively. The experimental data logger reliably stored all collected data without error to the micro-SD card. The experimental data logger can be considered low-cost and sufficiently accurate for monitoring air temperature and air relative humidity in aviaries, presenting field performance very close to the commercial data logger for air temperature measurement, and better performance than the commercial data logger for the measurement of air relative humidity.
Tipo:  Info:eu-repo/semantics/article
Idioma:  Inglês
Identificador:  http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1415-43662019001000787
Editor:  Departamento de Engenharia Agrícola - UFCG
Relação:  10.1590/1807-1929/agriambi.v23n10p787-793
Formato:  text/html
Fonte:  Revista Brasileira de Engenharia Agrícola e Ambiental v.23 n.10 2019
Direitos:  info:eu-repo/semantics/openAccess
Fechar
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional