Overall objective of this study was to evaluate the dispersion of aerosol plumes generated by a truck-mounted ultra low-volume (ULV) applicator and a hand-held thermal fogger under open field conditions. Experiments were also planned to determine the relative capture efficiencies of various sampling techniques in such applications. The ULV applicator was used at three travel speeds (8.5, 16.8, 24.8 km/h) and the thermal fogger at two release heights (0.6 and 1.1 m above ground) to investigate the effect of speed or release height on deposition at 6, 12, 24, and 48 m downwind. High volume air sampler (HVS), low volume air samplers (LVS), spinning cotton ribbon (CR) samplers, polypropylene green plastic cards (GC), acetate cards... |