Fast assessment of mineral constituents in grass by inductively coupled plasma optical emission spectrometry BABT
Santos,Éder José dos; Baika,Loana Mara; Herrmann,Amanda Beatriz; Kulik,Suzete; Sato,Charyane Satie; Santos,Arlene Bispo dos; Curtius,Adilson José.
A method for evaluating inorganic constituents in the grass by ICP OES is proposed. The samples were digested with nitric acid plus hydrogen peroxide in a microwave system. Seventeen samples were collected in the metropolitan area of Curitiba and Castro in the Paraná State, Brazil. The following elements were studied: Al, As, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se and Zn. The linear coefficients of the curves were higher than 0.999 and the precision, expressed as the relative standard deviation, which was below 10%, being considered adequate. The accuracy was validated by using the recovery test (recoveries from 80 to 107%) and by the analysis of botanical certified materials. For one sample, two other digestion procedures, using...
Tipo: Info:eu-repo/semantics/article Palavras-chave: ICP OES; Inorganic constituents; Acid digestion; PCA.
Ano: 2012 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132012000300017
Imagem não selecionada

Imprime registro no formato completo
Evaluation of arsenic and selenium in Brazilian soluble coffee by inductively coupled plasma atomic emission spectrometry with hydride generation BABT
Santos,Éder José dos; Oliveira,Elisabeth de.
A method for the evaluation of arsenic and selenium in soluble coffee by inductively coupled plasma atomic emission spectrometry with continuous hydride generation to attend the Brazilian food legislation is described. Samples were digested with nitric acid and hydrogen peroxide in a focused microwave system. Slow heating eliminated nitric acid and selenium (VI) was reduced to selenium (IV) by addition of 6 mol/L hydrochloric acid and heating at 90° C under a reflux system. The influence of sample acidity on sensitivity was investigated. Hydrochloric acid 6 mol/L was the most suitable reaction medium. Practical detection limits of 2.0mug/L for As and 1.0mu g/L for Se were achieved and attended the Brazilian food legislation. The results of recoveries on...
Tipo: Info:eu-repo/semantics/article Palavras-chave: ICP-AES; As; Se; Soluble coffee.
Ano: 2001 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132001000300003
Imagem não selecionada

Imprime registro no formato completo
Chemical quality of bottled mineral waters from markets of Curitiba-PR-Brazil BABT
Santos,Éder José dos; Oliveira Junior,Dasio Roberto de; Hermann,Amanda Beatriz; Sturgeon,Ralph Edward.
ABSTRACT Twenty-seven bottled mineral waters from local markets in Curitiba, State of Paraná, Brazil were analyzed for a number of constituents, including: pH, conductivity, total dissolved solids, hardness, HCO3 - and CO 3 2-, as well as Ca2+, Mg2+, Na+, K+, NH4 + , F-, Cl-, NO3 -, NO2 - and SO4 2- by ion chromatography (IC); Al, Ba, Cd, Cr, Cu, Fe, Li, Mn, Ni, Sr, V and Zn by inductively coupled plasma optical emission spectrometry (ICP OES); Hg by cold vapor generation-ICP OES and As, Pb, Sb and Se by ICP-mass spectrometry (ICP-MS). The obtained limits of quantitation (LOQ) were adequate for the determination of all analytes using the various analytical techniques. Results for the analysis of AccuStandard certified reference materials QCS-01-5,...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Bottled mineral waters; Elemental composition; Chemical quality; Principal component analysis.
Ano: 2016 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132016000100513
Imagem não selecionada

Imprime registro no formato completo
Simultaneous determination of Pb and Cd in seafood by ICP OES with on-line pre-concentration by solid phase extraction with amberlite XAD-4 after complex formation with DDTP BABT
Santos,Éder José dos; Santos,Arlene Bispo dos; Herrmann,Amanda Beatriz; Kulik,Suzete; Baika,Loana Mara; Tormen,Luciano; Curtius,Adilson José.
An on-line method for Cd and Pb pre-concentration and simultaneous determination in acid digested seafood by inductively coupled plasma optical emission spectrometry (ICP OES) was developed. The on-line pre-concentration was based on the complex formation of the analytes with the ammonium salt of O,O-diethyldithiophosphate (DDTP) and using the Amberlite XAD-4 resin as a solid support in a homemade column. Different conditions of the flow injection system, such as solutions flow rates, nebulizer pressure and eluent concentration were optimized. Three certified reference materials of lobster hepatopancreas, dogfish liver and fish protein, three samples of fish muscle and three samples of shrimp were digested with HNO3, H2O2 and H2SO4 in a microwave system...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Cd; Pb; ICP OES; Diethyldithiophosphate; XAD-4; Seafood; Solid phase extraction.
Ano: 2013 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132013000100017
Imagem não selecionada

Imprime registro no formato completo
ICP OES Determination of Contaminant Elements Leached from Food Packaging Films BABT
Santos,Éder José dos; Oliveira,Fernanda Mara Pimentel; Herrmann,Amanda Beatriz; Sturgeon,Ralph Edward.
ABSTRACT Determination of potential contaminants elements in food packing films arising from contact with acidic aqueous foods was undertaken by inductively coupled plasma optical emission spectrometry (ICP OES) in accordance with DIN EN 1186-1. Test sections from plastic films were totally immersed in 3% w/v CH3COOH used as the food simulant. Testing was conducted under three conditions: (1) 10 days at 40 ºC; (2) 30 min at 70 ºC and 10 days at 40 ºC; and (3) 30 min at 100 ºC and 10 days at 40 ºC. These time and temperature conditions were considered to be the most severe situations likely to be encountered in practice. Several different containers were investigated, including a borosilicate glass beaker, a glass bottle used for food canning, as well as...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Food packaging; ICP OES; Contaminant elements.
Ano: 2017 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132017000100424
Imagem não selecionada

Imprime registro no formato completo
Determination of trace metals in electrolytic copper by ICP OES and ICP-MS BABT
Santos,Éder José dos; Herrmann,Amanda Beatriz; Olkuszewski,José Luiz; Saint'Pierre,Tatiana D.; Curtius,Adilson José.
The performance of axial view ICP OES and ICP-MS techniques were compared through the determination of As, Fe, Mn, Pb, Sb and Sn in electrolytic copper. Samples were prepared by two procedures: 1. Total dissolution with 5 % v/v HNO3 and 2. Dissolution with 1.4 % v/v HNO3 plus 2.0 % v/v H2SO4, followed by separation of the Cu by electrodeposition. The methods were applied for the analysis of standard copper solutions, using calibration against aqueous solutions with or without the addition of Cu. The results obtained by the two techniques were similar, but the separation of Cu from the sample matrix proved to be more adequate for practical reasons.
Tipo: Info:eu-repo/semantics/article Palavras-chave: ICP-MS; Axial view ICP OES; Electrolytic copper; Electrodeposition.
Ano: 2005 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132005000600002
Registros recuperados: 6
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional