Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Ordenar por: 

RelevânciaAutorTítuloAnoImprime registros no formato resumido
Registros recuperados: 2
Primeira ... 1 ... Última
Imagem não selecionada

Imprime registro no formato completo
Subacute effects of a maximal exercise bout on endothelium-mediated vasodilation in healthy subjects BJMBR
Bousquet-Santos,K.; Soares,P.P.S.; Nóbrega,A.C.L..
We evaluated vascular reactivity after a maximal exercise test in order to determine whether the effect of exercise on the circulation persists even after interruption of the exercise. Eleven healthy sedentary volunteers (six women, age 28 ± 5 years) were evaluated before and after (10, 60, and 120 min) a maximal exercise test on a treadmill. Forearm blood flow (FBF) was measured by venous occlusion plethysmography before and during reactive hyperemia (RH). Baseline FBF, analyzed by the area under the curve, increased only at 10 min after exercise (P = 0.01). FBF in response to RH increased both at 10 and 60 min vs baseline (P = 0.004). Total excess flow for RH above baseline showed that vascular reactivity was increased up to 60 min after exercise (mean ±...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Vascular reactivity; Exercise test; Blood flow; Plethysmography.
Ano: 2005 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2005000400017
Imagem não selecionada

Imprime registro no formato completo
A semi-automatic computerized method to measure baroreflex-mediated heart rate responses that reduces interobserver variability BJMBR
Soares,P.P.S.; Ushizima,M.R.; Krieger,E.M.; Irigoyen,M.C.C..
Arterial baroreflex sensitivity estimated by pharmacological impulse stimuli depends on intrinsic signal variability and usually a subjective choice of blood pressure (BP) and heart rate (HR) values. We propose a semi-automatic method to estimate cardiovascular reflex sensitivity to bolus infusions of phenylephrine and nitroprusside. Beat-to-beat BP and HR time series for male Wistar rats (N = 13) were obtained from the digitized signal (sample frequency = 2 kHz) and analyzed by the proposed method (PRM) developed in Matlab language. In the PRM, time series were low-pass filtered with zero-phase distortion (3rd order Butterworth used in the forward and reverse direction) and presented graphically, and parameters were selected interactively. Differences...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Baroreflex sensitivity; Heart rate; Blood pressure; Phenylephrine; Nitroprusside.
Ano: 2005 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2005000600018
Registros recuperados: 2
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional