|
|
|
|
|
Santos,Mariane Gonçalves; Vitor,Ricardo Vilela; Nakamura,Maurício Gustavo; Morelini,Luana de Souza; Ferreira,Rafaela Scalco; Paiva,Alexandre Giusti; Azevedo,Luciana; Marques,Vanessa Bergamin Boralli; Martins,Isarita; Figueiredo,Eduardo Costa. |
Organophosphates (OPs) are widely used as pesticides, and its urinary metabolites as well as the blood cholinesterases (ChEs) activity have been reported as possible biomarkers for the assessment of this pesticide exposure. Moreover, the OPs can induce mutagenesis, and the bone marrow micronucleus test is an efficient way to assess this chromosomal damage. This paper reports a study carried out to verify the correlation among the disulfoton exposure, blood ChEs activity, urinary diethyl thiophosphate (DETP), and diethyl dithiophosphate (DEDTP), as well as micronucleated polychromatic erythrocytes (MNPCEs) frequency. Four groups of rats (n=12) were exposed to disulfoton at 0, 2.8, 4.7, and 6.6 mg kg-1 body weight. The blood ChEs activity, urinary DETP and... |
Tipo: Info:eu-repo/semantics/article |
Palavras-chave: Pesticides/exposure study; Organophosphate/exposure study; Disulfoton/exposure; Dialkyl phosphate/urinary excretion; Blood cholinesterase; Micronucleated polychromatic erythrocytes/frequency. |
Ano: 2013 |
URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502013000100016 |
| |
|
|
Alcântara,Adélia Maria Pimenta de Pádua; Vitor,Ricardo Vilela; Vieira,Elisabeth Pizzamiglio; Martins,Isarita. |
The aim of this study was to develop a method for simultaneous detection of antineoplastic drugs on gloves since, in occupational exposure, the main contamination route is through dermal contact, which may occur via prolonged contact with contaminated surfaces or materials. The assay was performed by liquid chromatography using the following conditions for the detection of 5-fluorouracil (5-FU), methotrexate (MTX) and paclitaxel (TAX): diode array detection and UV quantification at 195 nm for TAX, at 265 nm for 5-FU and at 302 nm for MTX; ODS column (250 x 4 mm, 5 μm) with a similar guard column; mobile phase consisted of water (pH 4)-methanol-acetonitrile (35:15:50, v/v/v) with a flow rate of 1 mL min-1. The method presented a linear range from 0.25 to 20... |
Tipo: Info:eu-repo/semantics/article |
Palavras-chave: Antineoplastic drugs/detection; Gloves/toxicologial analysis; High Performance Liquid Chromatography/toxicologial analysis; Occupational exposure. |
Ano: 2010 |
URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502010000400015 |
| |
|
|
|