Tanaka,K.; Sawatani,E.; Dias,G.A.; Shigueoka,E.M.; Campos,T.C.X.B.; Nakao,H.C.; Arashiro,F.. |
In order to obtain intravenous immunoglobulin G (iv IgG) of high quality from F-I+II+III or F-II+III pastes prepared by the Cohn method, we developed a chromatography process using ion exchange gels, Q-Sepharose FF and CM-Sepharose FF, and Sephacryl S-300 gel filtration. Viral inactivation was performed by incubating the preparation with pepsin at pH 4.0 at 35oC for 18 h. The characteristics of 28 batches produced by us were: yield 4.3 ± 0.2 g/l plasma, i.e., a recovery of 39.1 ± 1.8%; IgG subclasses distribution: IgG1 = 58.4%, IgG2 = 34.8%, IgG3 = 4.5% and IgG4 = 2.3%; IgG size distribution was 98.4% monomers, 1.2% dimers and 0.4% polymers and protein aggregates; anticomplement activity was less than 0.5 CH50/mg IgG, and prekallikrein activator activity... |
Tipo: Info:eu-repo/semantics/other |
Palavras-chave: Immunoglobulin G purification; Hemoderivative purification; Chromatographic procedures; High quality immunoglobulin G; Downstream process. |
Ano: 2000 |
URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2000000100004 |
| |