Sabiia Seb
PortuguêsEspañolEnglish
Embrapa
        Busca avançada

Botão Atualizar


Botão Atualizar

Ordenar por: 

RelevânciaAutorTítuloAnoImprime registros no formato resumido
Registros recuperados: 2
Primeira ... 1 ... Última
Imagem não selecionada

Imprime registro no formato completo
Regression Equation from Dual Energy X Ray Absorptiometry (DEXA) for Estimating Muscle Mass Segment International Journal of Morphology
Rodríguez Rodríguez,Fernando Javier; Almagiá Flores,Atilio Aldo; Berral de la Rosa,Francisco José.
Anthropometric methods used to estimate muscle mass (MM) do not specify values for body segments, a critical fact for individuals practicing physical activities or clinical diagnosis. In this study, 60 recreational athletes are anthropometrically evaluated and also undergo dual energy X-ray absorptiometry. Linear regression statistics is subsequently used to establish the constants allowing the obtaining of the segment MM. Three equations were obtained, one for the upper members: MMUL = (0.533*FAP) - (0.176*RAP) + (0.42*WP) + (0.282*SRL) - 19,985; a second equation for muscle mass of the lower members: MMLL = (0.186*H) - (0.158*LTTL) - (0.024*LTL) + (0451*LP) ­ 24.535; and the third one for the muscle mass of the trunk TrMM = (0.026*W) + (0.046*H) +...
Tipo: Journal article Palavras-chave: Anthropometry; Muscle mass; DEXA.
Ano: 2012 URL: http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022012000200031
Imagem não selecionada

Imprime registro no formato completo
Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Arq. Bras. Med. Vet. Zootec.
Borges,N.C.; Vasconcellos,R.S.; Canola,J.C.; Paula,F.J.A.; Carciofi,A.C.; Pereira,G.T..
A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were...
Tipo: Info:eu-repo/semantics/article Palavras-chave: Cat; Repeatability; DEXA.
Ano: 2008 URL: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000100037
Registros recuperados: 2
Primeira ... 1 ... Última
 

Empresa Brasileira de Pesquisa Agropecuária - Embrapa
Todos os direitos reservados, conforme Lei n° 9.610
Política de Privacidade
Área restrita

Embrapa
Parque Estação Biológica - PqEB s/n°
Brasília, DF - Brasil - CEP 70770-901
Fone: (61) 3448-4433 - Fax: (61) 3448-4890 / 3448-4891 SAC: https://www.embrapa.br/fale-conosco

Valid HTML 4.01 Transitional